Side duct connection HRV,149 CFM

Item Number: 40072

Airflow up to 149 cfm @ 0.4" PS serves 3-5 bedroom homes

Three speed ventilation control

External dry contacts for quick connection of remote controls

Compatible with Fantech's low-voltage controls

Easy access service door

Application

Fantech's side port connection HRV for budget conscious house projects.

How it works

the SHR 1504 unit brings a continuous supply of fresh air into a home while exhausting an equal amount of contaminated air. During winter, fresh incoming air is tempered by the heat that is transferred from the outgoing air so you save on energy costs, while during summer, the incoming air is pre-cooled if the house is equipped with an air cooling system. The SHR 1504 is equipped with automatic defrost mechanisms so you can use your HRV all year long.

Defrost cycle

A preset defrost sequence is activated at an outdoor air temperature of 23°F and lower. During the defrost sequence, the supply blower shuts down & the exhaust blower switches to high speed to maximize the effectiveness of the defrost strategy. The unit then returns to normal operation, and continues the cycle.

Technical parameters

Product
Voltage (nominal) 120 V
Frequency 60 Hz
Phase(s) 1~
Input power 156 W
Input current 1.3 A
Air flow 70 L/s
Static pressure 100 Pa
Certificate CSA, HVI
Exchanger
Exchanger type Heat recovery (aluminium)
Dimensions and weights
Weight 45.2 lb
Used for
Installation placement Horizontal
Heating Supply temperature Net airflow Consumed power Sensible recovery efficiency Apparent sensible effectiveness Latent recovery/moisture transfer

°F (°C)

cfm (L/s)

W

%

%

-

32 (0)

67 (31)

72

60

73

-0.11

32 (0)

109 (51)

98

59

70

0.00

32 (0)

161 (76)

144

55

63

0.00

-13 (-25)

68 (32)

73

56

77

-0.02

A B C D E Duct Size

2 1/4 (57)

23 1/3 (597)

2 5/8 (67)

17 3/8 (441)

16 1/8 (410)

6 (152)

Dimensional information is in inche (mm)

Fans

Two (2) factory-balanced fans with backward curved blades. Motors come with permanently lubricated, sealed ball-bearings to guarantee long life and maintenance-free operation.

Heat Recovery Core

Aluminum heat recovery core covered by a limited lifetime warranty. Core dimensions are 9” x 9” (229 x 229 mm) with a 15” (380 mm) depth. Our heat exchangers are designed and manufactured to withstand extreme temperature variations. 

Frost Control

A preset frost control sequence is activated at an outdoor air temperature of 23°F (-5°C) and lower. During the defrost sequence, the supply blower shuts down & the exhaust blower switches into high speed to maximize the effectiveness of the defrost strategy. The unit then returns to normal operation, and continues cycle.

Serviceability

Core, filters, fans and drain pan can be easily accessed through latched door. Core conveniently slides out on our new easy glide core guides. 17" (432 mm) of clearance is recommended for removal of core.

Case

24 gauge galvanized steel. Baked power-coated paint for a superior adhesion and resistance.

Insulation

Cabinet is fully insulated with 1” (25 mm) high density expanded polystyrene.

Filters

Two (2) washable electrostatic panel type air filters 8.5” (216mm) x 15” (380mm) x 0.125” (3mm).

Controls

External three (3) position (Low/Stand By/Medium) rocker switch that will offer continuous ventilation. Fantech offers a variety of external controls. (see accessories)

Installation

Unit is typically hung by using installation kit supplied with unit. Mounting bolts provided on top four (4) corners of unit.

Warranty

Limited lifetime on aluminum core, 7 year on motors, and 5 year on parts.

Requirements and standards

Complies with the UL 1812 requirements regulating the construction and installation of Heat Recovery Ventilators

Complies with the CSA C22.2 no. 113 Standard applicable to ventilators

Complies with the CSA F326 requirements regulating the installation of Heat Recovery Ventilators

Technical data was obtained from published results of test relating to CSA C439 Standards

HVI certified

COM6P Supply and Exhaust Hoods - Fantech Item Number: 40222 COM6P Supply and Exhaust Hoods

6" White Plastic Supply & Exhaust Hoods (pair)

.
ECO-TOUCH Pgrm Wall Ctrl - Fantech Item Number: 44929 ECO-TOUCH Pgrm Wall Ctrl

Touchscreen multi-function dehumidistat

.
EDF1 Multi-Func Ctrl - Fantech Item Number: 40375 EDF1 Multi-Func Ctrl

Low-Intermittent-High Wall Control

.
EDF7 Electronic Dehumidistat - Fantech Item Number: 44883 EDF7 Electronic Dehumidistat

multi-function, surface mount

.
Filter,MERV6,150 cfm,Repl.kit - Fantech Item Number: 414647 Filter,MERV6,150 cfm,Repl.kit .
Filter,MERV8,150 cfm,Repl.kit - Fantech Item Number: 414924 Filter,MERV8,150 cfm,Repl.kit

MERV8 Filter kit, 150 cfm, 2 pcs, 8.5"x15"

.
MDEH1 Low Voltage Dehumidistat - Fantech Item Number: 40172 MDEH1 Low Voltage Dehumidistat

2-wire mechanical dehumidistat, low voltage

.
MGE4 Metal Exhaust Grill - Fantech Item Number: 411106 MGE4 Metal Exhaust Grill

4" duct metal grille w/collar, exhaust

.
MGE5 Metal Exhaust Grill - Fantech Item Number: 411370 MGE5 Metal Exhaust Grill

5" duct metal grille w/collar, exhaust

.
MGE6 Metal Exhaust Grill - Fantech Item Number: 411371 MGE6 Metal Exhaust Grill

6" duct metal grille w/collar, exhaust

.
MGS4 Metal Supply Grill - Fantech Item Number: 411368 MGS4 Metal Supply Grill

4" duct metal grille w/collar, supply

.
MGS5 Metal Supply Grill - Fantech Item Number: 411369 MGS5 Metal Supply Grill

5" duct metal grille w/collar, supply

.
MGS6 Metal Supply Grill - Fantech Item Number: 411242 MGS6 Metal Supply Grill

6" duct metal grille w/collar, supply

.
RTS2 Pushbutton Timer - Fantech Item Number: 40164 RTS2 Pushbutton Timer

20 minutes push-button timer

.
RTS3 Pushbutton Timer - Fantech Item Number: 40376 RTS3 Pushbutton Timer

Electronic 20/40/60 minutes timer

.