SHR 1504 Fresh Air Appliance
Item #: 40072
Airflow up to 149 cfm @ 0.4" PS serves 3-5 bedroom homes
Three speed ventilation control
External dry contacts for quick connection of remote controls
Compatible with Fantech's low-voltage controls
Easy access service door
Application
Fantech's side port connection HRV for budget conscious house projects.
How it works
the SHR 1504 unit brings a continuous supply of fresh air into a home while exhausting an equal amount of contaminated air. During winter, fresh incoming air is tempered by the heat that is transferred from the outgoing air so you save on energy costs, while during summer, the incoming air is pre-cooled if the house is equipped with an air cooling system. The SHR 1504 is equipped with automatic defrost mechanisms so you can use your HRV all year long.
Defrost cycle
A preset defrost sequence is activated at an outdoor air temperature of 23°F and lower. During the defrost sequence, the supply blower shuts down & the exhaust blower switches to high speed to maximize the effectiveness of the defrost strategy. The unit then returns to normal operation, and continues the cycle.
Unit | ||
---|---|---|
Frequency | 60 | Hz |
Voltage (nominal) | 120 | V |
Phases | 1~ | |
Input current | 1.3 | A |
Input power | 156 | W |
Air flow | 148 | cfm |
Nominal max static pressure | 0.4 | in.wg |
Product type | Heat recovery unit |
Heat Exchanger | ||
---|---|---|
Heat exchanger | Heat recovery |
Others | ||
---|---|---|
Installation type | Horizontal |
Dimensions and weights | ||
---|---|---|
Weight | 45.2 | lb |
Certificates | ||
---|---|---|
Certificate | CSA, HVI |
Heating | Supply temperature | Net airflow | Consumed power | Sensible recovery efficiency | Apparent sensible effectiveness | Latent recovery/moisture transfer | |
°F (°C) |
cfm (L/s) |
W |
% |
% |
- |
||
32 (0) |
67 (31) |
72 |
60 |
73 |
-0.11 |
||
32 (0) |
109 (51) |
98 |
59 |
70 |
0.00 |
||
32 (0) |
161 (76) |
144 |
55 |
63 |
0.00 |
||
-13 (-25) |
68 (32) |
73 |
56 |
77 |
-0.02 |
A | B | C | D | E | Duct Size | |||||
2 1/4 (57) |
23 1/3 (597) |
2 5/8 (67) |
17 3/8 (441) |
16 1/8 (410) |
6 (152) |
|||||
Dimensional information is in inche (mm) |
||||||||||
Fans
Two (2) factory-balanced fans with backward curved blades. Motors come with permanently lubricated, sealed ball-bearings to guarantee long life and maintenance-free operation.
Heat Recovery Core
Aluminum heat recovery core covered by a limited lifetime warranty. Core dimensions are 9” x 9” (229 x 229 mm) with a 15” (380 mm) depth. Our heat exchangers are designed and manufactured to withstand extreme temperature variations.
Frost Control
A preset frost control sequence is activated at an outdoor air temperature of 23°F (-5°C) and lower. During the defrost sequence, the supply blower shuts down & the exhaust blower switches into high speed to maximize the effectiveness of the defrost strategy. The unit then returns to normal operation, and continues cycle.
Serviceability
Core, filters, fans and drain pan can be easily accessed through latched door. Core conveniently slides out on our new easy glide core guides. 17" (432 mm) of clearance is recommended for removal of core.
Case
24 gauge galvanized steel. Baked power-coated paint for a superior adhesion and resistance.
Insulation
Cabinet is fully insulated with 1” (25 mm) high density expanded polystyrene.
Filters
Two (2) washable electrostatic panel type air filters 8.5” (216mm) x 15” (380mm) x 0.125” (3mm).
Controls
External three (3) position (Low/Stand By/Medium) rocker switch that will offer continuous ventilation. Fantech offers a variety of external controls. (see accessories)
Installation
Unit is typically hung by using installation kit supplied with unit. Mounting bolts provided on top four (4) corners of unit.
Warranty
Limited lifetime on aluminum core, 7 year on motors, and 5 year on parts.
Requirements and standards
Complies with the UL 1812 requirements regulating the construction and installation of Heat Recovery Ventilators
Complies with the CSA C22.2 no. 113 Standard applicable to ventilators
Complies with the CSA F326 requirements regulating the installation of Heat Recovery Ventilators
Technical data was obtained from published results of test relating to CSA C439 Standards
HVI certified