ECOM Symbol ECOM Symbol

SHR 1400 Heat Rec Ventilator

Side duct connection HRV, 1428 cfm

Item Number: 99274

• Airflow up to 1428cfm @ 0.4" PS
• Push-push configuration
• Removable screw terminal for easy connection
• Dual service doors & reversible electrical box
• External three position switch (Low/Standby/High)
Application

The SHR 1400 Commercial Heat Recovery Ventilation system (HRV) complements today's tight buildings.

How it works

Fantech Heat Recovery Ventilators (HRV) are designed to supply air into a building while exhausting an equal amount of contaminated air to the outside. The aluminum heat exchanger core transfers sensible energy between air streams resulting in tempering of the supply air and reduced loads on the HVAC system.

Defrost cycle

A preset defrost sequence is activated at an outdoor air temperature of 23°F and lower. During the defrost sequence, the supply blower shuts down & the exhaust blower switches to high speed to maximize the effectiveness of the defrost strategy. The unit then returns to normal operation, and continues the cycle.

Technical parameters

Unit
Frequency 60 Hz
Voltage (nominal) 120 V
Phase(s) 1~
Input current 10.6 A
MCA 14.25 A
MOP 15 A
Input power 1,272 W
Air flow max 1,428 cfm
Static pressure 0.4 in.wg
Dimensions and weights
Weight 235.9 lb
Certificates
Certificate CSA, AHRI
Images Wiring - SHR 1400 Heat Rec Ventilator - Fantech Images Wiring - SHR 1400 Heat Rec Ventilator - Fantech
Supply Temperature Net Airflow Net Effectiveness

Sensible

Total

°F (°C)

cfm (L/s)

%

%

Heating

35 (1.7)

1410 (665)

55

36

35 (1.7)

1058 (499)

57

37

Cooling

95 (35)

1410 (665)

44

17

95 (35)

1058 (499)

47

18

Images Dimensions - SHR 1400 Heat Rec Ventilator - Fantech
A B C D E F G Drain Spout

51 2/5 (1306)

47 1/5 (1199)

24 (610)

8 (203)

21 1/2 (546)

35 (889)

25 3/4 (654)

1/2 (13)

Fans

Four (4) factory balanced fans with backward curved blades. Motors come with permanently lubricated sealed ball bearings, (TOP) thermal overload protected and maintenance-free operation.

Heat recovery core

The heat recovery cores are fixed plate cross-flow heat exchanger using aluminum alloy 1100 and capable of transferring sensible heat between air streams. The heat recovery cores are engineered with a turbulence inducing geometry in order to maximize heat transfer while allowing an effective evacuation of condensate. The plates are hemmed to avoid cross-contamination of airstreams. The SHR 1400 features three cores, each 12" x 12" (305 mm x 305 mm) with a 15" (380 mm) depth.

Defrost

A preset frost control sequence is initiated if the outdoor temperature falls below the set point of 23°F (-5°C). During the initial stage, the supply blower shuts down & the exhaust blower switches into high speed to eliminate frost build-up in the core. The unit then returns to normal operation for the final stage of the frost control sequence at which time the sequence is repeated if the outdoor air temperatures is still below the set point.

Serviceability

Cores, filters and drain pan can be accessed easily from both sides of the HRV from hinged access panels. Cores conveniently slide out with only 15" (380 mm) clearance. Blowers can be accessed from both side of the HRV from fastened access panels. Blowers are easily removed by taking off the access panel and sliding the motor plates out of the HRV. A quick connect allows for fast inspection of blowers.

Case

22 gauge galvanized steel. Baked powder coated paint.

Insulation

Insulated with 1 in. (25 mm) fiberglass with FSK facing and 2 in. (50 mm) of foil-faced high density polystyrene foam on the outdoor air side for condensation control.

Filters

The exhaust and fresh air streams are protected by MERV1 washable filters constructed to meet UL 900. Optional MERV6 filters are direct replacement to the MERV1. Use of MERV6 filters will add an additional system pressure of 0.88 in.wg (220 Pa) at 1400 cfm (661 l/s). Additional MERV Rated filters available upon request.

Controls

External three (3) position (Low/Stand By/High) rocker switch that will offer continuous ventilation. In addition Fantech offers a variety of external controls.

Mounting

Unit may be suspended by using threaded rod, not supplied, or placed on a platform. Unit shall be adaptable for easy service of electrical components.

Warranty

Limited lifetime on aluminum core, 3 years on motors, and 3 years on parts

Requirements and standards
• Complies with the UL 1812 requirements regulating the construction and installation of Heat Recovery Ventilators
• Complies with the CSA C22.2 no. 113 Standard applicable to ventilators
• Technical data was obtained from published results of test relating to AHRI 1060 Standards
BPM 08-24P Bypass module - Fantech Item Number: 99302 BPM 08-24P Bypass module

3-way bypass module for recirculation, 8"x24" duct

.
CO2RT-R Transmitter - Fantech Item Number: 99315 CO2RT-R Transmitter

0-2000ppm w/relay, room mounting

.
ECO-Feel - Fantech Item Number: 414729 ECO-Feel

Dehumidistat & IAQ sensor, w/o display, 4 wire

.
ECO-Touch® IAQ - Fantech Item Number: 414727 ECO-Touch® IAQ

Touchscreen multi-function dehumidistat, 4 wires

.
EDF1 Multi-Func Ctrl - Fantech Item Number: 40375 EDF1 Multi-Func Ctrl

Low-Intermittent-High Wall Control

.
EDF7 Electronic Dehumidistat - Fantech Item Number: 44883 EDF7 Electronic Dehumidistat

multi-function, surface mount

.
EFD 24-8, Damper, TFB24 - Fantech Item Number: 99305 EFD 24-8, Damper, TFB24

24"x8" Shutter damper with spring-return actuators, 24V

.
Filter,MERV8,1100-1400,Repl.ki - Fantech Item Number: 414934 Filter,MERV8,1100-1400,Repl.ki

MERV8 Filter kit, LC, 1100-1400cfm, 6 pcs, 11.5"x15"

.
IR 4 Iris Damper - Fantech Item Number: 411234 IR 4 Iris Damper

4" iris damper w/manual adjuster

.
IR 5 Iris Damper - Fantech Item Number: 411235 IR 5 Iris Damper

5" iris damper w/manual adjuster

.
IR 6 Iris Damper - Fantech Item Number: 411236 IR 6 Iris Damper

6" iris damper w/manual adjuster

.
IR 8 Iris Damper - Fantech Item Number: 411237 IR 8 Iris Damper

8" iris damper w/manual adjuster

.
MDEH1 Low Voltage Dehumidistat - Fantech Item Number: 40172 MDEH1 Low Voltage Dehumidistat

2-wire mechanical dehumidistat, low voltage

.
MGE 4 Metal Exhaust Grill - Fantech Item Number: 411106 MGE 4 Metal Exhaust Grill

4" duct metal grille w/collar, exhaust

.
MGE 5 Metal Exhaust Grill - Fantech Item Number: 411370 MGE 5 Metal Exhaust Grill

5" duct metal grille w/collar, exhaust

.
MGE 6 Metal Exhaust Grill - Fantech Item Number: 411371 MGE 6 Metal Exhaust Grill

6" duct metal grille w/collar, exhaust

.
MGE 8 Metal Exhaust Grill - Fantech Item Number: 411244 MGE 8 Metal Exhaust Grill

8" duct metal grille w/collar, exhaust

.
MGS 5 Metal Supply Grill - Fantech Item Number: 411369 MGS 5 Metal Supply Grill

5" duct metal grille w/collar, supply

.
MGS 6 Metal Supply Grill - Fantech Item Number: 411242 MGS 6 Metal Supply Grill

6" duct metal grille w/collar, supply

.
MGS 8 Metal Supply Grill - Fantech Item Number: 411243 MGS 8 Metal Supply Grill

8" duct metal grille w/collar, supply

.
Replacement filter kit, MERV13 - Fantech Item Number: 414937 Replacement filter kit, MERV13

Replacement filter kit, MERV13, (1100-1400 cfm)

.
RTS2 Pushbutton Timer - Fantech Item Number: 40164 RTS2 Pushbutton Timer

20 minutes push-button timer

.
RTS5 Pushbutton Timer - Fantech Item Number: 44794 RTS5 Pushbutton Timer

Pushbutton Timer, 20/40/60 minutes

.