10" exterior wall exhaust fan, white, 120V, 1~
Item #: 44866
This exterior exhaust fan extracts stale, humid, and polluted air from indoor areas. Application examples include bathrooms, utility rooms, residential garages, etc.
• Outdoor installation ensures fan motor noise stays outside
• Galvanized housing with painted cover minimizes corrosion potential
• Operable in air temperatures up to 140°F
• Neoprene seals ensure minimal leakage in high temperature ranges
• Built-in thermal overload protection with automatic reset
• Rubber gasket for ease of duct installation
• Five-year factory warranty
With the motor in the airstream, the RVF fan provides the constant dissipation of heat build-up even at partial load that gives the fan best-in-class longevity and reliability backed by an industry leading warranty.
Nominal data | ||
---|---|---|
Voltage (nominal) | 120 | V |
Frequency | 60 | Hz |
Phases | 1~ | |
Input power | 309 | W |
Input current | 2.59 | A |
Impeller speed | 1,526 | rpm |
Air flow | max 1,248 | cfm |
Temperature of transported air | max 104 | °F |
Max temperature of transported air, when speed controlled | 104 | °F |
Protection/Classification | ||
---|---|---|
Enclosure class, motor | IP44 | |
Insulation class | B |
Dimensions and weights | ||
---|---|---|
Duct dimension; Circular, inlet | 10 | in. |
Duct dimension; Circular, inlet | 10 | in. |
Duct dimension; Circular, outlet | 10 | in. |
Weight | 31.6 | lb |
Optional | ||
---|---|---|
Duct connection type | Circular | |
Motor type | AC |
CFM Table |
|||||||||||||
Model |
Rated Power |
Voltage/Phase |
Max Amp. |
RPM |
0.0"Ps |
0.2"Ps |
0.4"Ps |
0.6"Ps |
0.8"Ps |
1.0"Ps |
1.5"Ps |
Sones |
Max Ps |
W |
V/~ |
A |
min-1 |
CFM |
|||||||||
RVF 102) |
112 |
120/1 |
0.94 |
1500 |
793 |
706 |
309 |
495 |
356 |
242 |
- |
11.1† |
1.28 |
RVF 10L2) |
211 |
120/1 |
2.10 |
1700 |
1065 |
988 |
912 |
832 |
736 |
621 |
214 |
14.8† |
1.68 |
RVF 10XL2) |
312 |
120/1 |
2.61 |
1600 |
1248 |
1161 |
1068 |
972 |
875 |
764 |
384 |
16.0‡ |
1.94 |
Performance certified is for installation type C-Ducted Inlet, Free Outlet. |
|||||||||||||
Performance ratings do not include the effects of appurtenances (accessories). |
|||||||||||||
Speed (RPM) is nominal. Performance is based on actual speed of test. |
|||||||||||||
The sound ratings shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International Standard 301. |
|||||||||||||
Values shown are for: Installation Type C: free outlet hemispherical sone levels. |
|||||||||||||
†Sones are calculated at 0.2” (static pressure in inches W.G.) |
|||||||||||||
‡Sones are calculated at 0.4” (static pressure in inches W.G.) |
|||||||||||||
2)AMCA performance and cULus safety certified. |
Model | A | B | C | D | E | F | G | H | I |
RVF 10 |
10 (254) |
17 7/8 (454) |
21 1/4 (540) |
10 (254) |
5 7/8 (149) |
7 3/8 (188) |
8 1/16 (205) |
9 1/8 (232) |
2 3/4 (70) |
RVF 10L |
10 (254) |
17 7/8 (454) |
21 1/4 (540) |
10 (254) |
5 7/8 (149) |
8 1/8 (206) |
8 1/16 (205) |
9 1/8 (232) |
2 3/4 (70) |
RVF 10XL |
10 (254) |
17 7/8 (454) |
21 1/4 (540) |
10 (254) |
5 7/8 (149) |
8 1/8 (206) |
8 1/16 (205) |
9 1/8 (232) |
2 3/4 (70) |
Dimensions in inches (mm) |
GUIDE SPECIFICATION
Specifier Notes: This guide specification is written in Construction Specifications Institute (CSI) 3-Part Format in accordance with The CSI Construction Specifications Practice Guide, MasterFormat, SectionFormat, and PageFormat.
Specifier Notes: This Section must be carefully reviewed and edited by the Architect or Engineer to meet the requirements of the Project and local building code. Coordinate this Section with Division 01, other specification sections, and the Drawings. Delete all Specifier Notes after editing this Section.
Section numbers and titles are based on MasterFormat 2014 Update.
SECTION 23 34 00
HVAC FANS
Specifier Notes: This Section covers Fantech RVF Series wall mount exhaust fans with alternating current (AC) motors. Consult Fantech for assistance in editing this Section as required for the Project.
PART 1. GENERAL
1.1 SECTION INCLUDES
A. Wall mount exhaust fans with alternating current (AC) motors.
1.2 RELATED REQUIREMENTS
Specifier Notes: Edit the following list of related sections as required for the Project. Limit the list to sections with specific information that the reader might expect to find in this Section but is specified elsewhere.
A. Section 23 31 00 – HVAC Ducts and Casings.
B. Section 26 05 00 – Common Work Results for Electrical.
1.3 REFERENCE STANDARDS
Specifier Notes: List reference standards used elsewhere in this Section, complete with designations and titles. Delete reference standards from the following list not used in the edited Section.
A. Air Movement and Control Association International (AMCA) (www.amca.org):
1. AMCA 211 – Certified Ratings Program - Product Rating Manual for Fan Air Performance.
B. Underwriting Laboratory (UL) (https://productiq.ulprospector.com/en):
1. UL 507- Electric Fans
2. CSA 22.2 No 113- Fans and Ventilators
1.4 PREINSTALLATION MEETINGS
Specifier Notes: Edit the Preinstallation Meetings article as required for the Project. Delete article if not required.
A. Convene preinstallation meeting [1 week] [2 weeks] before start of Work of this Section.
B. Require attendance of parties directly affecting Work of this Section, including Contractor, Architect, installer, and manufacturer’s representative.
C. Review the Following:
1. Materials
2. Installation
3. Adjusting
4. Protection
5. Coordination with other Work
1.5 SUBMITTALS
Specifier Notes: Edit the Submittals article as required for the Project. Delete submittals not required.
A. Comply with Division 01.
B. Product Data: Submit manufacturer’s product data, including installation instructions.
C. Shop Drawings: Submit manufacturer’s shop drawings, including plans, elevations, sections, and details.
1. Wiring Diagrams: Indicate wiring for each item of equipment and interconnections between items of equipment.
2. Include manufacturer’s names, model numbers, ratings, power requirements, equipment layout, device arrangement, complete wiring point-to-point diagrams, and conduit layouts.
D. Manufacturer’s Certification: Submit manufacturer’s certification that materials comply with specified requirements and are suitable for intended application.
E. Operation and Maintenance Data:
1. Submit manufacturer’s operation and maintenance manual; including the following:
a. Operation, maintenance, adjustment, and cleaning instructions.
b. Troubleshooting guide
c. Parts list
d. Electrical wiring diagrams if required.
2. Provide detailed information required for Owner to properly operate and maintain equipment.
F. Warranty Documentation: Submit manufacturer’s standard warranty.
1.6 QUALITY ASSURANCE
A. Manufacturer’s Qualifications: Manufacturer regularly engaged in the manufacturing of wall mount exhaust fans to that specified for a minimum of 10 years.
B. Installer's Qualifications:
1. Installer regularly engaged in installation of wall mount exhaust fans of similar type to that specified for a minimum of 5 years.
2. Use persons trained for installation of wall mount exhaust fans.
1.7 DELIVERY, STORAGE, AND HANDLING
A. Delivery Requirements: Deliver materials to site in manufacturer’s original, unopened containers and packaging, with labels clearly identifying product name and manufacturer.
B. Storage and Handling Requirements:
1. Store and handle materials in accordance with manufacturer’s instructions.
2. Keep materials in manufacturer’s original, unopened containers and packaging until installation.
3. Store materials in clean, dry area indoors.
4. Keep materials from freezing.
5. Protect materials during storage, handling, and installation to prevent damage.
1.8 WARRANTY
Warranty Period: 5 years
PART 2. PRODUCTS
2.1 MANUFACTURERS
A. Manufacturer: Fantech Inc., 10048 Industrial Blvd., Lenexa, Kansas 66215. Phone 800-747-6217. www.fantech.net. ussupport@fantech.net.
Specifier Notes: Specify if substitutions will be permitted.
B. Substitutions: [Not permitted] [Comply with Division 01].
C. Single Source: Provide materials from single manufacturer.
2.2 HVAC FANS
A. Wall mount exhaust fans with alternating current (AC) motors: RVF Series
1. AMCA Air Seal
2. cULus Listed
A. Additional Evaluation(s): Outdoor Use
Specifier Notes: Specify wall mount exhaust fans models as required for the Project. Delete models not required.
B. Model: “RVF 10”
1. Inlet Diameter: 10 inches
2. Housing Dimensions: 21-1/4 inches x 17-7/8 inches x 10 inches (H x W x D)
3. Inlet Connection Collar: 1 inch with a rubber gasket
4. Casing Material: Galvanized Sheet Metal, powder coated, white, RAL9016. Allows to open the cover for maintenance if required
5. Motor: Alternating current external-rotor motor
6. Speed Control: by altering supply voltage via an external stepless controller
7. Motor Protection: electronically protected
8. Blades: Backward curved
9. Voltage: 120 V
10. Frequency: 50/60 Hz
11. Nominal Voltage Range: 100 to 130 V
12. Phase: 1
13. Maximum Airflow: 792 cfm
14. RPM: 1,458
15. Power Rating, Motor: 113 W
16. Current: 0.95 A
17. Operational Temperature: minus 13 to 104 degrees F
18. Weight: 27.1 lbs
19. Motor Insulation Class: B
20. Motor Enclosure Class: IP44
C. Model: “RVF 10L”
1. Inlet Diameter: 10 inches
2. Housing Dimensions: 21-1/4 inches x 17-7/8 inches x 10 inches (H x W x D)
3. Inlet Connection Collar: 1 inch with a rubber gasket
4. Casing Material: Galvanized Sheet Metal, powder coated, white, RAL9016. Allows to open the cover for maintenance if required
5. Motor: Alternating current external-rotor motor
6. Speed Control: by altering supply voltage via an external stepless controller
7. Motor Protection: electronically protected
8. Blades: Backward curved
9. Voltage: 120 V
10. Frequency: 50/60 Hz
11. Nominal Voltage Range: 100 to 130 V
12. Phase: 1
13. Maximum Airflow: 1,066 cfm
14. RPM: 1,688
15. Power Rating, Motor: 207 W
16. Current: 1.78 A
17. Operational Temperature: minus 13 to 104 degrees F
18. Weight: 31.4 lbs
19. Motor Insulation Class: B
20. Motor Enclosure Class: IP44
C. Model: “RVF 10XL”
1. Inlet Diameter: 10 inches
2. Housing Dimensions: 21-1/4 inches x 17-7/8 inches x 10 inches (H x W x D)
3. Inlet Connection Collar: 1 inch with a rubber gasket
4. Casing Material: Galvanized Sheet Metal, powder coated, white, RAL9016. Allows to open the cover for maintenance if required
5. Motor: Alternating current external-rotor motor
6. Speed Control: by altering supply voltage via an external stepless controller
7. Motor Protection: electronically protected
8. Blades: Backward curved
9. Voltage: 120 V
10. Frequency: 50/60 Hz
11. Nominal Voltage Range: 100 to 130 V
12. Phase: 1
13. Maximum Airflow: 1,248 cfm
14. RPM: 1,526
15. Power Rating, Motor: 309 W
16. Current: 2.59 A
17. Operational Temperature: minus 13 to 104 degrees F
18. Weight: 9.8 lbs
19. Motor Insulation Class: B
20. Motor Enclosure Class: IP44
2.3 ACCESSORIES
A. Silencer for Circular Duct
Specifier Notes: Delete accessories not required.
1. Model: [“LD 10”]
2. Insulation Thickness: 2 inches.
B. Mounting Clamp for Circular Duct
Specifier Notes: Delete accessories not required.
1. Model: [“FC 10”]
2. Material: Galvanized sheet metal with 1/3 inch neoprene lining
3. Width: 2-1/3 inches
4. Clamps Together: 2 screws
5. Quantity: 2 pcs per kit
C. External Remotely Mounted Speed Controller
Specifier Notes: Delete if not required.
1. Model: WC15
2. Remotely mounted manual-speed control for air flow adjustments and balancing.
3. Voltage: 120V
4. Amperage: 5A max
5. Enclosure class: IP54
D. Back-draft Damper for Circular Duct
Specifier Notes: Delete if not required.
1. Model: [“RSK10”]
2. Material housing: 24GA, G90 galvanized sheet metal
3. Material blades: aluminum H14, spring-loaded
4. Material rubber gasket: Synthetic polymer
PART 3. EXECUTION
3.1 EXAMINATION
A. Examine areas to receive wall mount exhaust fans.
B. Notify Architect of conditions that would adversely affect installation or subsequent use.
C. Do not begin installation until unacceptable conditions are corrected.
3.2 INSTALLATION
A. Install wall mount exhaust fans in accordance with manufacturer’s instructions at locations indicated on the Drawings.
B. Attach duct work to inlet connection collars of wall mount exhaust fans in accordance with manufacturer’s instructions.
C. Electrical: Install electrical power to wall mount exhaust fans as specified in Section 26 05 00.
3.3 ADJUSTING
A. Adjust wall mount exhaust fans for proper operation in accordance with manufacturer’s instructions.
3.4 PROTECTION
A. Protect installed wall mount exhaust fans from damage during construction.
END OF SECTION