Fantech
This product has been discontinued
 
ECOM Symbol ECOM Symbol

RVF 10L Ext Centrifugal Fan

10" exterior wall exhaust fan, white, 120V, 1~

Item #: 44865

This exterior exhaust fan extracts stale, humid, and polluted air from indoor areas. Application examples include bathrooms, utility rooms, residential garages, etc.

 

• Outdoor installation ensures fan motor noise stays outside

• Galvanized housing with painted cover minimizes corrosion potential

• Operable in air temperatures up to 140°F

• Neoprene seals ensure minimal leakage in high temperature ranges

• Built-in thermal overload protection with automatic reset

• Rubber gasket for ease of duct installation

• Five-year factory warranty

 

With the motor in the airstream, the RVF fan provides the constant dissipation of heat build-up even at partial load that gives the fan best-in-class longevity and reliability backed by an industry leading warranty.

Technical parameters

Nominal data
Voltage (nominal) 120 V
Frequency 60 Hz
Phases 1~
Input power 207 W
Input current 1.78 A
Impeller speed 1,688 rpm
Air flow max 1,066 cfm
Temperature of transported air max 104 °F
Max temperature of transported air, when speed controlled 104 °F
Protection/Classification
Enclosure class, motor IP44
Insulation class B
Dimensions and weights
Duct dimension; Circular, inlet 10 in.
Duct dimension; Circular, inlet 10 in.
Duct dimension; Circular, outlet 10 in.
Weight 31.4 lb
Optional
Duct connection type Circular
Motor type AC
Images Wiring - RVF 10L Ext Centrifugal Fan - Fantech

CFM Table

Model

Rated Power

Voltage/Phase

Max Amp.

RPM

0.0"Ps

0.2"Ps

0.4"Ps

0.6"Ps

0.8"Ps

1.0"Ps

1.5"Ps

Sones

Max Ps

W

V/~

A

min-1

CFM

RVF 102)

112

120/1

0.94

1500

793

706

309

495

356

242

-

11.1†

1.28

RVF 10L2)

211

120/1

2.10

1700

1065

988

912

832

736

621

214

14.8†

1.68

RVF 10XL2)

312

120/1

2.61

1600

1248

1161

1068

972

875

764

384

16.0‡

1.94

Performance certified is for installation type C-Ducted Inlet, Free Outlet.

Performance ratings do not include the effects of appurtenances (accessories).

Speed (RPM) is nominal. Performance is based on actual speed of test.

The sound ratings shown are loudness values in fan sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA International Standard 301.

Values shown are for: Installation Type C: free outlet hemispherical sone levels.

†Sones are calculated at 0.2” (static pressure in inches W.G.)

‡Sones are calculated at 0.4” (static pressure in inches W.G.)

2)AMCA performance and cULus safety certified.

Images Dimensions - RVF 10L Ext Centrifugal Fan - Fantech
Model A B C D E F G H I

RVF 10

10 (254)

17 7/8 (454)

21 1/4 (540)

10 (254)

5 7/8 (149)

7 3/8 (188)

8 1/16 (205)

9 1/8 (232)

2 3/4 (70)

RVF 10L

10 (254)

17 7/8 (454)

21 1/4 (540)

10 (254)

5 7/8 (149)

8 1/8 (206)

8 1/16 (205)

9 1/8 (232)

2 3/4 (70)

RVF 10XL

10 (254)

17 7/8 (454)

21 1/4 (540)

10 (254)

5 7/8 (149)

8 1/8 (206)

8 1/16 (205)

9 1/8 (232)

2 3/4 (70)

Dimensions in inches (mm)

GUIDE SPECIFICATION

Specifier Notes: This guide specification is written in Construction Specifications Institute (CSI) 3-Part Format in accordance with The CSI Construction Specifications Practice Guide, MasterFormat, SectionFormat, and PageFormat.

Specifier Notes: This Section must be carefully reviewed and edited by the Architect or Engineer to meet the requirements of the Project and local building code. Coordinate this Section with Division 01, other specification sections, and the Drawings. Delete all Specifier Notes after editing this Section.

Section numbers and titles are based on MasterFormat 2014 Update.

SECTION 23 34 00

HVAC FANS

Specifier Notes: This Section covers Fantech RVF Series wall mount exhaust fans with alternating current (AC) motors. Consult Fantech for assistance in editing this Section as required for the Project.

PART 1. GENERAL

1.1 SECTION INCLUDES

A.     Wall mount exhaust fans with alternating current (AC) motors.

1.2 RELATED REQUIREMENTS

Specifier Notes: Edit the following list of related sections as required for the Project. Limit the list to sections with specific information that the reader might expect to find in this Section but is specified elsewhere.

A. Section 23 31 00 – HVAC Ducts and Casings.

B. Section 26 05 00 – Common Work Results for Electrical.

1.3 REFERENCE STANDARDS

Specifier Notes: List reference standards used elsewhere in this Section, complete with designations and titles. Delete reference standards from the following list not used in the edited Section.

A. Air Movement and Control Association International (AMCA) (www.amca.org):

1. AMCA 211 – Certified Ratings Program - Product Rating Manual for Fan Air Performance.

B. Underwriting Laboratory (UL) (https://productiq.ulprospector.com/en):

1. UL 507- Electric Fans

2. CSA 22.2 No 113- Fans and Ventilators

1.4 PREINSTALLATION MEETINGS

Specifier Notes: Edit the Preinstallation Meetings article as required for the Project. Delete article if not required.

A. Convene preinstallation meeting [1 week] [2 weeks] before start of Work of this Section.

B. Require attendance of parties directly affecting Work of this Section, including Contractor, Architect, installer, and manufacturer’s representative.

C. Review the Following:

1. Materials

2. Installation

3. Adjusting

4. Protection

5. Coordination with other Work

1.5 SUBMITTALS

Specifier Notes: Edit the Submittals article as required for the Project. Delete submittals not required.

A. Comply with Division 01.

B. Product Data: Submit manufacturer’s product data, including installation instructions.

C. Shop Drawings: Submit manufacturer’s shop drawings, including plans, elevations, sections, and details.

1. Wiring Diagrams: Indicate wiring for each item of equipment and interconnections between items of equipment.

2. Include manufacturer’s names, model numbers, ratings, power requirements, equipment layout, device arrangement, complete wiring point-to-point diagrams, and conduit layouts.

D. Manufacturer’s Certification: Submit manufacturer’s certification that materials comply with specified requirements and are suitable for intended application.

E. Operation and Maintenance Data:

1. Submit manufacturer’s operation and maintenance manual; including the following:

a. Operation, maintenance, adjustment, and cleaning instructions.

b. Troubleshooting guide

c. Parts list

d. Electrical wiring diagrams if required.

2. Provide detailed information required for Owner to properly operate and maintain equipment.

F. Warranty Documentation: Submit manufacturer’s standard warranty.

1.6 QUALITY ASSURANCE

A.     Manufacturer’s Qualifications: Manufacturer regularly engaged in the manufacturing of wall mount exhaust fans to that specified for a minimum of 10 years.

B.     Installer's Qualifications:

1.     Installer regularly engaged in installation of wall mount exhaust fans of similar type to that specified for a minimum of 5 years.

2.     Use persons trained for installation of wall mount exhaust fans.

1.7 DELIVERY, STORAGE, AND HANDLING

A.     Delivery Requirements: Deliver materials to site in manufacturer’s original, unopened containers and packaging, with labels clearly identifying product name and manufacturer.

B.     Storage and Handling Requirements:

1.     Store and handle materials in accordance with manufacturer’s instructions.

2.     Keep materials in manufacturer’s original, unopened containers and packaging until installation.

3.     Store materials in clean, dry area indoors.

4.     Keep materials from freezing.

5.     Protect materials during storage, handling, and installation to prevent damage.

1.8 WARRANTY

Warranty Period: 5 years

PART 2. PRODUCTS

2.1 MANUFACTURERS

A.     Manufacturer: Fantech Inc., 10048 Industrial Blvd., Lenexa, Kansas 66215. Phone 800-747-6217. www.fantech.net. ussupport@fantech.net.

Specifier Notes: Specify if substitutions will be permitted.

B. Substitutions: [Not permitted] [Comply with Division 01].

C. Single Source: Provide materials from single manufacturer.

2.2 HVAC FANS

A.     Wall mount exhaust fans with alternating current (AC) motors: RVF Series

1. AMCA Air Seal

2. cULus Listed

A. Additional Evaluation(s): Outdoor Use

Specifier Notes: Specify wall mount exhaust fans models as required for the Project. Delete models not required.

B. Model: “RVF 10”

1. Inlet Diameter: 10 inches

2. Housing Dimensions: 21-1/4 inches x 17-7/8 inches x 10 inches (H x W x D)

3. Inlet Connection Collar: 1 inch with a rubber gasket

4. Casing Material: Galvanized Sheet Metal, powder coated, white, RAL9016. Allows to open the cover for maintenance if required

5. Motor: Alternating current external-rotor motor

6. Speed Control: by altering supply voltage via an external stepless controller

7. Motor Protection: electronically protected

8. Blades: Backward curved

9. Voltage: 120 V

10. Frequency: 50/60 Hz

11. Nominal Voltage Range: 100 to 130 V

12. Phase: 1

13. Maximum Airflow: 792 cfm

14. RPM: 1,458

15. Power Rating, Motor: 113 W

16. Current: 0.95 A

17. Operational Temperature: minus 13 to 104 degrees F

18. Weight: 27.1 lbs

19. Motor Insulation Class: B

20. Motor Enclosure Class: IP44

C. Model: “RVF 10L”

1. Inlet Diameter: 10 inches

2. Housing Dimensions: 21-1/4 inches x 17-7/8 inches x 10 inches (H x W x D)

3. Inlet Connection Collar: 1 inch with a rubber gasket

4. Casing Material: Galvanized Sheet Metal, powder coated, white, RAL9016. Allows to open the cover for maintenance if required

5. Motor: Alternating current external-rotor motor

6. Speed Control: by altering supply voltage via an external stepless controller

7. Motor Protection: electronically protected

8. Blades: Backward curved

9. Voltage: 120 V

10. Frequency: 50/60 Hz

11. Nominal Voltage Range: 100 to 130 V

12. Phase: 1

13. Maximum Airflow: 1,066 cfm

14. RPM: 1,688

15. Power Rating, Motor: 207 W

16. Current: 1.78 A

17. Operational Temperature: minus 13 to 104 degrees F

18. Weight: 31.4 lbs

19. Motor Insulation Class: B

20. Motor Enclosure Class: IP44

C. Model: “RVF 10XL”

1. Inlet Diameter: 10 inches

2. Housing Dimensions: 21-1/4 inches x 17-7/8 inches x 10 inches (H x W x D)

3. Inlet Connection Collar: 1 inch with a rubber gasket

4. Casing Material: Galvanized Sheet Metal, powder coated, white, RAL9016. Allows to open the cover for maintenance if required

5. Motor: Alternating current external-rotor motor

6. Speed Control: by altering supply voltage via an external stepless controller

7. Motor Protection: electronically protected

8. Blades: Backward curved

9. Voltage: 120 V

10. Frequency: 50/60 Hz

11. Nominal Voltage Range: 100 to 130 V

12. Phase: 1

13. Maximum Airflow: 1,248 cfm

14. RPM: 1,526

15. Power Rating, Motor: 309 W

16. Current: 2.59 A

17. Operational Temperature: minus 13 to 104 degrees F

18. Weight: 9.8 lbs

19. Motor Insulation Class: B

20. Motor Enclosure Class: IP44

2.3 ACCESSORIES

A. Silencer for Circular Duct

Specifier Notes: Delete accessories not required.

1. Model: [“LD 10”]

2. Insulation Thickness: 2 inches.

B. Mounting Clamp for Circular Duct

Specifier Notes: Delete accessories not required.

1. Model: [“FC 10”]

2. Material: Galvanized sheet metal with 1/3 inch neoprene lining

3. Width: 2-1/3 inches

4. Clamps Together: 2 screws

5. Quantity: 2 pcs per kit

C. External Remotely Mounted Speed Controller

Specifier Notes: Delete if not required.

1. Model: WC15

2. Remotely mounted manual-speed control for air flow adjustments and balancing.

3. Voltage: 120V

4. Amperage: 5A max

5. Enclosure class: IP54

D. Back-draft Damper for Circular Duct

Specifier Notes: Delete if not required.

1. Model: [“RSK10”]

2. Material housing: 24GA, G90 galvanized sheet metal

3. Material blades: aluminum H14, spring-loaded

4. Material rubber gasket: Synthetic polymer

PART 3. EXECUTION

3.1 EXAMINATION

A.     Examine areas to receive wall mount exhaust fans.

B.     Notify Architect of conditions that would adversely affect installation or subsequent use.

C.     Do not begin installation until unacceptable conditions are corrected.

3.2 INSTALLATION

A.     Install wall mount exhaust fans in accordance with manufacturer’s instructions at locations indicated on the Drawings.

B.     Attach duct work to inlet connection collars of wall mount exhaust fans in accordance with manufacturer’s instructions.

C.     Electrical: Install electrical power to wall mount exhaust fans as specified in Section 26 05 00.

3.3 ADJUSTING

A.     Adjust wall mount exhaust fans for proper operation in accordance with manufacturer’s instructions.

3.4 PROTECTION

A.     Protect installed wall mount exhaust fans from damage during construction.

END OF SECTION

FD60EM Electronic timer - Fantech
Item #: 411386
FD60EM Electronic timer

10/20/30/60 min, 1-gang box mount, 1800W max load, 15A

.
FH 20 Dehumidistat - Fantech
Item #: 410727
FH 20 Dehumidistat

surface mount, 7.5A

.
IPF05 Speed control - Fantech
Item #: 484164
IPF05 Speed control

1-gang box mount, w/ decora plate, 120V, 5A

.
WC 15 Speed control - Fantech
Item #: 411102
WC 15 Speed control

w/on-off switch, surface mount, 120V, 5A

.
FIDT 10 Insulated Flex Duct - Fantech
Item #: 411322
FIDT 10 Insulated Flex Duct

10" flexible duct, R4.2 Rating, 25ft

.
HL 42 Kitchen Hood Liner - Fantech
Item #: 56046
HL 42 Kitchen Hood Liner

42" stainless fascia hood liner, 2 hal bulbs 10" duct collar

.
HL 48 Kitchen Hood Liner - Fantech
Item #: 56045
HL 48 Kitchen Hood Liner

48" stainless fascia hood liner, 3 hal bulbs 10" duct collar

.
RSK 10 Backdraft Damper - Fantech
Item #: 411116
RSK 10 Backdraft Damper

10" Back-draft damper for circular duct, single

.
FC 10 Mounting Clamps (2 pcs) - Fantech
Item #: 411122
FC 10 Mounting Clamps (2 pcs)

Mounting Clamps, 10" (2 pcs)

.
LD 10 Silencer - Fantech
Item #: 411286
LD 10 Silencer

for 10" circular ducts, 2" insulation, rubber gaskets

.