SHR 3005R HRV

Art. no.: 40214

• Airflow up to 253 cfm @ 0.4" PS serves 3-7 bedroom homes
• External dry contacts for quick connection of remote controls
• Easy access service door

Application

The SHR 3005R's double core configuration provides the greater thermal efficiency needed for homes being built to a higher energy standard.

How it works

The incoming air passes through a first, then a second heat exchanger to provide maximum heat recovery. During winter, fresh incoming air is tempered by the heat that is transferred from the outgoing air so you save on energy costs, while during summer, the incoming air is pre-cooled if the house is equipped with an air cooling system.

Defrost cycle

During the defrost sequence, a motorized damper temporarily blocks the incoming fresh air stream so that the warm air from the house can circulate through the HRV. The exhaust blower shuts down and the supply blower switches into high speed to maximize the effectiveness of the defrost strategy. During this cycle, household odors from the kitchen or bathroom are prevented from entering the home and the unit will not create negative pressure.

In stock earliest delivery 29.02.19 Show availability
  • Aug 29, 2018
  • Sep 09, 2018
  • 500
  • 500

Technical parameter

Product
Voltage (Nominal) 120 V
Frequency 60 Hz
Phase(s) 1~
Input power 336 W
Input current 2.8 A
Air flow 119 L/s
Static pressure 100 Pa
Certificate CSA, HVI
Exchanger
Exchanger type Heat recovery (aluminium)
Dimensions and weights
Weight 89.9 lb
Used for
Installation placement Horizontal
Supply temperature Net airflow Consumed power Sensible recovery efficiency Apparent sensible effectiveness Latent recovery/moisture transfer

°F (°C)

cfm (L/s)

W

%

%

-

Heating

32 (0)

64 (30)

126

76

91

0.02

32 (0)

117 (55)

212

78

92

0.01

32 (0)

157 (74)

262

78

91

-0.09

-13 (-25)

121 (57)

224

72

91

0.09

-13 (-25)

117 (55)

220

72

-

-

Total recovery efficiency

%

Cooling

95 (35)

115 (54)

206

18

95 (35)

159 (74)

260

17

A B C D Duct Size

50 7/8 (1292)

2 1/5 (56)

22 1/5 (564)

17 3/8 (441)

6 (152)

Dimensional information is in inches (mm)

Fans

Four (4) factory-balanced fans with backward curved blades. Motors come with permanently lubricated, sealed ball-bearings to guarantee long life and maintenance-free operation.

Heat Recovery Core

Aluminum heat recovery core covered by a limited lifetime warranty. Core dimensions are 12” x 12” (305 x 305 mm) with a 15” (380 mm) depth. Our heat exchangers are designed and manufactured to withstand extreme temperature variations. 

Defrost

During the defrost sequence, a motorized damper temporarily blocks the incoming fresh air stream so that the warm air from the house can circulate through the HRV. The exhaust blower shuts down and the supply blower switches into high speed to maximize the effectiveness of the defrost strategy. During this cycle, household odors from the kitchen or bathroom are prevented from entering the home and the unit will not create negative pressure.

Serviceability

Core, filters, fans and drain pan can be easily accessed through latched door. Core conveniently slides out on our new easy glide core guides. 17" (432 mm) of clearance is recommended for removal of core.

Case 

24 gauge galvanized steel. Baked powder coated paint.

Insulation

Cabinet is fully insulated with 1” (25 mm) high density expanded polystyrene.

Filters

Two (2) washable electrostatic panel type air filters 11.75” (298mm) x 15” (380mm) x 0.125” (3mm).

Controls

External three (3) position (Low/Stand By/Medium) rocker switch that will offer continuous ventilation. Fantech offers a variety of external controls. (see accessories)

Installation

Unit is typically hung by using installation kit supplied with unit. Mounting bolts provided on top four (4) corners of unit.

Warranty

Limited lifetime on aluminum core, 7 year on motors, and 5 year on parts.

Requirements and standards
• Complies with the UL 1812 requirements regulating the construction and installation of Heat Recovery Ventilators
• Complies with the CSA C22.2 no. 113 Standard applicable to ventilators
• Complies with the CSA F326 requirements regulating the installation of Heat Recovery Ventilators
• Technical data was obtained from published results of test relating to CSA C439 Standards