Fantech
 
ECOM Symbol ECOM Symbol

RVF 8XL Ext Centrif Fan

8" exterior wall exhaust fan, white, 120V, 1~

Item #: 40044

This exterior exhaust fan extracts stale, humid, and polluted air from indoor areas. Application examples include bathrooms, utility rooms, residential garages, etc.

 

• Outdoor installation ensures fan motor noise stays outside

• Galvanized housing with painted cover minimizes corrosion potential

• Operable in air temperatures up to 60°C

• Neoprene seals ensure minimal leakage in high temperature ranges

• Built-in thermal overload protection with automatic reset

• Rubber gasket for ease of duct installation

• Five-year factory warranty

With the motor in the airstream, the RVF fan provides the constant dissipation of heat build-up even at partial load that gives the fan best-in-class longevity and reliability backed by an industry leading warranty.

Technical parameters

Nominal data
Voltage (nominal) 115 V
Frequency 60 Hz
Phases 1~
Input power 139 W
Input current 1.34 A
Impeller speed 2 925 rpm
Air flow max 211 L/s
Capacitance of capacitor 10 µF
Temperature of transported air max 60 °C
Max temperature of transported air, when speed controlled 60 °C
Protection/Classification
Enclosure class, motor IP44
Insulation class B
Certificate HVI, cULus
Data according to ErP
ErP ready Not ErP relevant
Dimensions and weights
Duct dimension; Circular, inlet 8 in.
Duct dimension; Circular, outlet 8 in.
Weight 12.7 lb
Optional
Duct connection type Circular
Motor type AC
Material Metal
Images Wiring - RVF 8XL Ext Centrif Fan - Fantech
HVI Certified Rating(s)

Static Pressure

(In. Wg.)

Rated Airflow

(CFM)

Rated Power

(Watts)

0.10

430

130

Images Dimensions - RVF 8XL Ext Centrif Fan - Fantech
Model A B C D E F G H I

RVF 4

4 (102)

10 1/4 (260)

13 (330)

6 (152)

2 3/4 (70)

5 1/8 (130)

6 1/2 (165)

4 1/16 (103)

1 (25)

RVF 4XL

4 (102)

10 1/4 (260)

13 (330)

6 (152)

2 3/4 (70)

5 1/8 (130)

5 1/4 (133)

5 1/4 (133)

1 (25)

RVF 6

6 (152)

10 1/4 (260)

13 (330)

6 (152)

2 3/4 (70)

5 1/8 (130)

5 1/4 (133)

5 9/32 (134)

1 (25)

RVF 6XL

6 (152)

14 1/4 (362)

17 (432)

6 (152)

2 3/4 (70)

7 1/8 (181)

7 3/8 (187)

7 1/16 (179)

1 (25)

RVF 8XL

8 (203)

14 1/4 (362)

17 (432)

6 (152)

2 3/4 (70)

7 1/8 (181)

7 3/8 (187)

7 1/16 (179)

1 (25)

Dimensions in inches (mm)

GUIDE SPECIFICATION

Specifier Notes: This guide specification is written in Construction Specifications Institute (CSI) 3-Part Format in accordance with The CSI Construction Specifications Practice Guide, MasterFormat, SectionFormat, and PageFormat.

Specifier Notes: This Section must be carefully reviewed and edited by the Architect or Engineer to meet the requirements of the Project and local building code. Coordinate this Section with Division 01, other specification sections, and the Drawings. Delete all Specifier Notes after editing this Section.

Section numbers and titles are based on MasterFormat 2014 Update.

SECTION 23 34 00

HVAC FANS

Specifier Notes: This Section covers Fantech RVF Series wall mount exhaust fans with alternating current (AC) motors. Consult Fantech for assistance in editing this Section as required for the Project.

PART 1. GENERAL

1.1 SECTION INCLUDES

A.     Wall mount exhaust fans with alternating current (AC) motors.

1.2 RELATED REQUIREMENTS

Specifier Notes: Edit the following list of related sections as required for the Project. Limit the list to sections with specific information that the reader might expect to find in this Section but is specified elsewhere.

A. Section 23 31 00 – HVAC Ducts and Casings.

B. Section 26 05 00 – Common Work Results for Electrical.

1.3 REFERENCE STANDARDS

Specifier Notes: List reference standards used elsewhere in this Section, complete with designations and titles. Delete reference standards from the following list not used in the edited Section.

A.     Home Ventilation Institute (HVI) (https://www.hvi.org/hvi-certified-products-directory/):

1. HVI 916 – Listed and Tested Accordingly

B. Canadian Standards Association (CSA) (https://www.csagroup.org/testing-certification/product- listing/):

1. UL 507- Electric Fans

2. CSA 22.2 No 113- Fans and Ventilators

1.4 PREINSTALLATION MEETINGS

Specifier Notes: Edit the Preinstallation Meetings article as required for the Project. Delete article if not required.

A. Convene preinstallation meeting [1 week] [2 weeks] before start of Work of this Section.

B. Require attendance of parties directly affecting Work of this Section, including Contractor, Architect, installer, and manufacturer’s representative.

C. Review the Following:

1. Materials

2. Installation

3. Adjusting

4. Protection

5. Coordination with other Work

1.5 SUBMITTALS

Specifier Notes: Edit the Submittals article as required for the Project. Delete submittals not required.

A. Comply with Division 01.

B. Product Data: Submit manufacturer’s product data, including installation instructions.

C. Shop Drawings: Submit manufacturer’s shop drawings, including plans, elevations, sections, and details.

1. Wiring Diagrams: Indicate wiring for each item of equipment and interconnections between items of equipment.

2. Include manufacturer’s names, model numbers, ratings, power requirements, equipment layout, device arrangement, complete wiring point-to-point diagrams, and conduit layouts.

D. Manufacturer’s Certification: Submit manufacturer’s certification that materials comply with specified requirements and are suitable for intended application.

E. Operation and Maintenance Data:

1. Submit manufacturer’s operation and maintenance manual; including the following:

a. Operation, maintenance, adjustment, and cleaning instructions.

b. Troubleshooting guide

c. Parts list

d. Electrical wiring diagrams if required.

2. Provide detailed information required for Owner to properly operate and maintain equipment.

F. Warranty Documentation: Submit manufacturer’s standard warranty.

1.6 QUALITY ASSURANCE

A.     Manufacturer’s Qualifications: Manufacturer regularly engaged in the manufacturing of wall mount exhaust fans to that specified for a minimum of 10 years.

B.     Installer's Qualifications:

1.     Installer regularly engaged in installation of wall mount exhaust fans of similar type to that specified for a minimum of 5 years.

2.     Use persons trained for installation of wall mount exhaust fans.

1.7 DELIVERY, STORAGE, AND HANDLING

A.     Delivery Requirements: Deliver materials to site in manufacturer’s original, unopened containers and packaging, with labels clearly identifying product name and manufacturer.

B.     Storage and Handling Requirements:

1.     Store and handle materials in accordance with manufacturer’s instructions.

2.     Keep materials in manufacturer’s original, unopened containers and packaging until installation.

3.     Store materials in clean, dry area indoors.

4.     Keep materials from freezing.

5.     Protect materials during storage, handling, and installation to prevent damage.

1.8 WARRANTY

Warranty Period: 5 years

PART 2. PRODUCTS

2.1 MANUFACTURERS

A.     Manufacturer: Fantech Inc., 10048 Industrial Blvd., Lenexa, Kansas 66215. Phone 800-747-6217. www.fantech.net. ussupport@fantech.net.

Specifier Notes: Specify if substitutions will be permitted.

B. Substitutions: [Not permitted] [Comply with Division 01].

C. Single Source: Provide materials from single manufacturer.

2.2 HVAC FANS

A.     Wall mount exhaust fans with alternating current (AC) motors: RVF Series

1. cCSAus

A. Additional Evaluation(s): Outdoor Use

2. HVI 916

Specifier Notes: Specify wall mount exhaust fans models as required for the Project. Delete models not required.

B. Model: “RVF 4”

1. Inlet Diameter: 4 inches

2. Housing Dimensions: 13 inches x 10-1/4 inches x 6 inches (H x W x D)

3. Inlet Connection Collar: 1 inch with a rubber gasket

4. Casing Material: Galvanized Sheet Metal, powder coated, white, RAL9016. Allows to open the cover for maintenance if required

5. Motor: Alternating current external-rotor motor

6. Speed Control: by altering supply voltage via an external stepless controller

7. Motor Protection: electronically protected

8. Blades: Backward curved

9. Voltage: 120 V

10. Frequency: 50/60 Hz

11. Nominal Voltage Range: 100 to 130 V

12. Phase: 1

13. Maximum Airflow: 136 cfm

14. RPM: 3,084

15. Power Rating, Motor: 18 W

16. Current: 0.49 A

17. Operational Temperature: minus 13 to 140 degrees F

18. Weight: 7.4 lbs

19. Motor Insulation Class: B

20. Motor Enclosure Class: IP44

B. Model: “RVF 4XL”

1. Inlet Diameter: 4 inches

2. Housing Dimensions: 13 inches x 10-1/4 inches x 6 inches (H x W x D)

3. Inlet Connection Collar: 1 inch with a rubber gasket

4. Casing Material: Galvanized Sheet Metal, powder coated, white, RAL9016. Allows to open the cover for maintenance if required

5. Motor: Alternating current external-rotor motor

6. Speed Control: by altering supply voltage via an external stepless controller

7. Motor Protection: electronically protected

8. Blades: Backward curved

9. Voltage: 120 V

10. Frequency: 50/60 Hz

11. Nominal Voltage Range: 100 to 130 V

12. Phase: 1

13. Maximum Airflow: 189 cfm

14. RPM: 2,504

15. Power Rating, Motor: 91 W

16. Current: 0.79 A

17. Operational Temperature: minus 13 to 140 degrees F

18. Weight: 7.4 lbs

19. Motor Insulation Class: B

20. Motor Enclosure Class: IP44

B. Model: “RVF 6”

1. Inlet Diameter: 6 inches

2. Housing Dimensions: 13 inches x 10-1/4 inches x 6 inches (H x W x D)

3. Inlet Connection Collar: 1 inch with a rubber gasket

4. Casing Material: Galvanized Sheet Metal, powder coated, white, RAL9016. Allows to open the cover for maintenance if required

5. Motor: Alternating current external-rotor motor

6. Speed Control: by altering supply voltage via an external stepless controller

7. Motor Protection: electronically protected

8. Blades: Backward curved

9. Voltage: 120 V

10. Frequency: 50/60 Hz

11. Nominal Voltage Range: 100 to 130 V

12. Phase: 1

13. Maximum Airflow: 242 cfm

14. RPM: 2,379

15. Power Rating, Motor: 93 W

16. Current: 0.75 A

17. Operational Temperature: minus 13 to 140 degrees F

18. Weight: 8.8 lbs

19. Motor Insulation Class: B

20. Motor Enclosure Class: IP44

C. Model: “RVF 6XL”

1. Inlet Diameter: 6 inches

2. Housing Dimensions: 17 inches x 14-1/4 inches x 6 inches (H x W x D)

3. Inlet Connection Collar: 1 inch with a rubber gasket

4. Casing Material: Galvanized Sheet Metal, powder coated, white, RAL9016. Allows to open the cover for maintenance if required

5. Motor: Alternating current external-rotor motor

6. Speed Control: by altering supply voltage via an external stepless controller

7. Motor Protection: electronically protected

8. Blades: Backward curved

9. Voltage: 120 V

10. Frequency: 50/60 Hz

11. Nominal Voltage Range: 100 to 130 V

12. Phase: 1

13. Maximum Airflow: 381 cfm

14. RPM: 3,044

15. Power Rating, Motor: 148 W

16. Current: 1.32 A

17. Operational Temperature: minus 13 to 140 degrees F

18. Weight: 8.6 lbs

19. Motor Insulation Class: B

20. Motor Enclosure Class: IP44

D. Model: “RVF 8XL”

1. Inlet Diameter: 8 inches

2. Housing Dimensions: 17 inches x 14-1/4 inches x 6 inches (H x W x D)

3. Inlet Connection Collar: 1 inch with a rubber gasket

4. Casing Material: Galvanized Sheet Metal, powder coated, white, RAL9016. Allows to open the cover for maintenance if required

5. Motor: Alternating current external-rotor motor

6. Speed Control: by altering supply voltage via an external stepless controller

7. Motor Protection: electronically protected

8. Blades: Backward curved

9. Voltage: 120 V

10. Frequency: 50/60 Hz

11. Nominal Voltage Range: 100 to 130 V

12. Phase: 1

13. Maximum Airflow: 378 cfm

14. RPM: 2,925

15. Power Rating, Motor: 150 W

16. Current: 1.34 A

17. Operational Temperature: minus 13 to 140 degrees F

18. Weight: 12.7 lbs

19. Motor Insulation Class: B

20. Motor Enclosure Class: IP44

2.3 ACCESSORIES

A. Silencer for Circular Duct

Specifier Notes: Delete accessories not required.

1. Model: [“LD 4”] [“LD 6”] [“LD 8”]

2. Insulation Thickness: 2 inches

3. Material: galvanized steel

B. Mounting Clamp for Circular Duct

Specifier Notes: Delete accessories not required.

1. Model: [“FC 4”] [“FC 6”] [“FC 8”]

2. Material: Galvanized sheet metal with 1/3 inch neoprene lining

3. Width: 2-1/3 inches

4. Clamps Together: 2 screws

5. Quantity: 2 pcs per kit

C. External Remotely Mounted Speed Controller

Specifier Notes: Delete if not required.

1. Model: WC15

2. Remotely mounted manual-speed control for air flow adjustments and balancing.

3. Voltage: 120V

4. Amperage: 5A max

5. Enclosure class: IP54

D. Back-draft Damper for Circular Duct

Specifier Notes: Delete if not required.

1. Model: [“RSK 4”] [“RSK 6”] [“RSK 8”]

2. Material housing: 24GA, G90 galvanized sheet metal

3. Material blades: aluminum H14, spring-loaded

4. Material rubber gasket: Synthetic polymer

PART 3. EXECUTION

3.1 EXAMINATION

A.     Examine areas to receive wall mount exhaust fans.

B.     Notify Architect of conditions that would adversely affect installation or subsequent use.

C.     Do not begin installation until unacceptable conditions are corrected.

3.2 INSTALLATION

A.     Install wall mount exhaust fans in accordance with manufacturer’s instructions at locations indicated on the Drawings.

B.     Attach duct work to inlet connection collars of wall mount exhaust fans in accordance with manufacturer’s instructions.

C.     Electrical: Install electrical power to wall mount exhaust fans as specified in Section 26 05 00.

3.3 ADJUSTING

A.     Adjust wall mount exhaust fans for proper operation in accordance with manufacturer’s instructions.

3.4 PROTECTION

A.     Protect installed wall mount exhaust fans from damage during construction.

END OF SECTION

FD60EM Electronic timer - Fantech
Item #: 411386
FD60EM Electronic timer

10/20/30/60 min, 1-gang box mount, 1800W max load, 15A

.
WC 15 Speed control - Fantech
Item #: 411102
WC 15 Speed control

w/on-off switch, surface mount, 120V, 5A

.
HL 30 Kitchen Hood Liner - Fantech
Item #: 56048
HL 30 Kitchen Hood Liner

30" stainless fascia hood liner, 2 hal bulbs 8" duct collar

.
HL 36 Kitchen Hood Liner - Fantech
Item #: 56047
HL 36 Kitchen Hood Liner

36" stainless fascia hood liner, 2 hal bulbs 8" duct collar

.
RSK 8 Backdraft Damper - Fantech
Item #: 411115
RSK 8 Backdraft Damper

8" Back-draft damper for circular duct, single

.
LD 8 Silencer - Fantech
Item #: 411125
LD 8 Silencer

for 8" circular ducts, 2" insulation, rubber gaskets

.
MGE8 Metal Exhaust Grill - Fantech
Item #: 411244
MGE8 Metal Exhaust Grill

8" duct metal grille w/collar, exhaust

.